{"product_id":"mil-dtl-27500-spec-55-shielded-cable-m22759-32-22-sold-by-the-foot","title":"MIL-DTL-27500 Spec 55 Shielded Cable – M22759\/32-22 (Sold by the Foot)","description":"\u003ch2 data-end=\"718\" data-start=\"654\"\u003eProfessional Motorsport Shielded Wire – Spec 55 \/ MIL-C-27500 22AWG\u003c\/h2\u003e\n\u003cp data-end=\"890\" data-start=\"720\"\u003eWe now offer genuine motorsport-grade MIL-DTL-27500 shielded cable built with M22759\/32 tin-plated copper conductors and cross-linked modified Tefzel (XLETFE) insulation. These are 22AWG conductor sizes for minimum Cross Width.\u003c\/p\u003e\n\u003cp data-end=\"916\" data-start=\"892\"\u003eCommonly referred to as:\u003c\/p\u003e\n\u003cul data-end=\"1034\" data-start=\"918\"\u003e\n\u003cli data-end=\"933\" data-start=\"918\"\u003e\n\u003cp data-end=\"933\" data-start=\"920\"\u003eMIL-C-27500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"951\" data-start=\"934\"\u003e\n\u003cp data-end=\"951\" data-start=\"936\"\u003eMIL-DTL-27500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"968\" data-start=\"952\"\u003e\n\u003cp data-end=\"968\" data-start=\"954\"\u003eNEMA WC27500\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"986\" data-start=\"969\"\u003e\n\u003cp data-end=\"986\" data-start=\"971\"\u003eSPEC 55 cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"999\" data-start=\"987\"\u003e\n\u003cp data-end=\"999\" data-start=\"989\"\u003e55A wire\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1034\" data-start=\"1000\"\u003e\n\u003cp data-end=\"1034\" data-start=\"1002\"\u003eTE Raychem WC-27500 equivalent\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1169\" data-start=\"1036\"\u003eThis is the same style of shielded cable used in professional motorsport harnesses, aerospace wiring, and high-end ECU installations.\u003c\/p\u003e\n\u003cp data-end=\"1255\" data-start=\"1171\"\u003eAvailable by the foot with in-stock quantities displayed. Spool options coming soon.\u003c\/p\u003e\n\u003chr data-end=\"1260\" data-start=\"1257\"\u003e\n\u003ch2 data-end=\"1289\" data-start=\"1262\"\u003eAvailable Configurations\u003c\/h2\u003e\n\u003cp data-end=\"1310\" data-start=\"1291\"\u003eWe currently offer:\u003c\/p\u003e\n\u003cul data-end=\"1391\" data-start=\"1312\"\u003e\n\u003cli data-end=\"1341\" data-start=\"1312\"\u003e\n\u003cp data-end=\"1341\" data-start=\"1314\"\u003eSingle Conductor Shielded\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1366\" data-start=\"1342\"\u003e\n\u003cp data-end=\"1366\" data-start=\"1344\"\u003e2-Conductor Shielded\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1391\" data-start=\"1367\"\u003e\n\u003cp data-end=\"1391\" data-start=\"1369\"\u003e3-Conductor Shielded\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1474\" data-start=\"1393\"\u003eAdditional conductor counts and spool options will be added as inventory expands.\u003c\/p\u003e\n\u003chr data-end=\"1479\" data-start=\"1476\"\u003e\n\u003ch2 data-end=\"1519\" data-start=\"1481\"\u003eCable Construction \u0026amp; Specifications\u003c\/h2\u003e\n\u003cp data-end=\"1835\" data-start=\"1521\"\u003e\u003cstrong data-end=\"1539\" data-start=\"1521\"\u003eSpecification:\u003c\/strong\u003e MIL-DTL-27500 (NEMA WC27500)\u003cbr data-end=\"1571\" data-start=\"1568\"\u003e\u003cstrong data-end=\"1585\" data-start=\"1571\"\u003eConductor:\u003c\/strong\u003e M22759\/32 tin-plated copper\u003cbr data-end=\"1616\" data-start=\"1613\"\u003e\u003cstrong data-end=\"1639\" data-start=\"1616\"\u003ePrimary Insulation:\u003c\/strong\u003e Cross-linked modified Tefzel (XLETFE)\u003cbr data-end=\"1680\" data-start=\"1677\"\u003e\u003cstrong data-end=\"1691\" data-start=\"1680\"\u003eShield:\u003c\/strong\u003e Tin-plated copper braid\u003cbr data-end=\"1718\" data-start=\"1715\"\u003e\u003cstrong data-end=\"1735\" data-start=\"1718\"\u003eOuter Jacket:\u003c\/strong\u003e Cross-linked modified Tefzel (XLETFE)\u003cbr data-end=\"1776\" data-start=\"1773\"\u003e\u003cstrong data-end=\"1795\" data-start=\"1776\"\u003eVoltage Rating:\u003c\/strong\u003e 600V\u003cbr data-end=\"1803\" data-start=\"1800\"\u003e\u003cstrong data-end=\"1826\" data-start=\"1803\"\u003eTemperature Rating:\u003c\/strong\u003e +150°C\u003c\/p\u003e\n\u003cp data-end=\"1938\" data-start=\"1837\"\u003eComparable to 55A11X1 and other SPEC 55 constructions used in professional motorsport harness builds.\u003c\/p\u003e\n\u003chr data-end=\"1943\" data-start=\"1940\"\u003e\n\u003ch2 data-end=\"1966\" data-start=\"1945\"\u003eIdeal Applications\u003c\/h2\u003e\n\u003cp data-end=\"2043\" data-start=\"1968\"\u003eThis cable is designed for high-noise, signal-sensitive circuits including:\u003c\/p\u003e\n\u003cul data-end=\"2282\" data-start=\"2045\"\u003e\n\u003cli data-end=\"2076\" data-start=\"2045\"\u003e\n\u003cp data-end=\"2076\" data-start=\"2047\"\u003eCrank position sensor (CKP) such as the \u003ca title=\"Honda K24 Crank Angle Sensor (CAS) Connector – 3-Pin (Top \u0026amp; Bottom Keyway Options)\" href=\"https:\/\/www.vtecinnovations.com\/products\/k24-crank-angle-sensor-connector-3-pin?utm_source=copyToPasteBoard\u0026amp;utm_medium=product-links\u0026amp;utm_content=web\"\u003e\u003cstrong data-start=\"1195\" data-end=\"1231\"\u003eK24 Crank Angle Sensor connector\u003c\/strong\u003e.\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2106\" data-start=\"2077\"\u003e\n\u003cp data-end=\"2106\" data-start=\"2079\"\u003eCam position sensor (CMP)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2123\" data-start=\"2107\"\u003e\n\u003cp data-end=\"2123\" data-start=\"2109\"\u003eKnock sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2147\" data-start=\"2124\"\u003e\n\u003cp data-end=\"2147\" data-start=\"2126\"\u003eWheel speed sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2168\" data-start=\"2148\"\u003e\n\u003cp data-end=\"2168\" data-start=\"2150\"\u003eCAN bus circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2195\" data-start=\"2169\"\u003e\n\u003cp data-end=\"2195\" data-start=\"2171\"\u003eShielded analog inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2218\" data-start=\"2196\"\u003e\n\u003cp data-end=\"2218\" data-start=\"2198\"\u003eECU trigger inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2246\" data-start=\"2219\"\u003e\n\u003cp data-end=\"2246\" data-start=\"2221\"\u003eFlex fuel sensor wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2282\" data-start=\"2247\"\u003e\n\u003cp data-end=\"2282\" data-start=\"2249\"\u003eMotorsport data logging systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2296\" data-start=\"2284\"\u003ePerfect for:\u003c\/p\u003e\n\u003cul data-end=\"2458\" data-start=\"2298\"\u003e\n\u003cli data-end=\"2323\" data-start=\"2298\"\u003e\n\u003cp data-end=\"2323\" data-start=\"2300\"\u003eHaltech installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2350\" data-start=\"2324\"\u003e\n\u003cp data-end=\"2350\" data-start=\"2326\"\u003eFuelTech installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2375\" data-start=\"2351\"\u003e\n\u003cp data-end=\"2375\" data-start=\"2353\"\u003eMoTeC harness builds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2409\" data-start=\"2376\"\u003e\n\u003cp data-end=\"2409\" data-start=\"2378\"\u003eK-swap shielded sensor wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2458\" data-start=\"2410\"\u003e\n\u003cp data-end=\"2458\" data-start=\"2412\"\u003eProfessional motorsport harness construction\u003cbr\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"2463\" data-start=\"2460\"\u003e\n\u003ch2 data-end=\"2501\" data-start=\"2465\"\u003eWhy Use MIL-27500 Shielded Cable?\u003c\/h2\u003e\n\u003cp data-end=\"2580\" data-start=\"2503\"\u003eUnlike generic automotive shielded wire, MIL-DTL-27500 construction provides:\u003c\/p\u003e\n\u003cul data-end=\"2766\" data-start=\"2582\"\u003e\n\u003cli data-end=\"2612\" data-start=\"2582\"\u003e\n\u003cp data-end=\"2612\" data-start=\"2584\"\u003eAerospace-grade insulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2645\" data-start=\"2613\"\u003e\n\u003cp data-end=\"2645\" data-start=\"2615\"\u003eSuperior chemical resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2676\" data-start=\"2646\"\u003e\n\u003cp data-end=\"2676\" data-start=\"2648\"\u003eHigh temperature tolerance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2708\" data-start=\"2677\"\u003e\n\u003cp data-end=\"2708\" data-start=\"2679\"\u003eExcellent EMI\/RFI shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"2766\" data-start=\"2709\"\u003e\n\u003cp data-end=\"2766\" data-start=\"2711\"\u003eLong-term durability in harsh engine bay environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2856\" data-start=\"2768\"\u003eThis is the correct way to wire crank and cam circuits in high-performance applications.\u003c\/p\u003e\n\u003chr data-end=\"2861\" data-start=\"2858\"\u003e\n\u003ch2 data-end=\"2890\" data-start=\"2863\"\u003eIn-Stock \u0026amp; Ready to Ship\u003c\/h2\u003e\n\u003cp data-end=\"3010\" data-start=\"2892\"\u003eWe maintain real-time inventory on this product. What is listed as available is physically in stock and ready to ship.\u003c\/p\u003e\n\u003cp data-end=\"3128\" data-start=\"3012\"\u003eOrders ship via expedited 2-day service to ensure builders can complete shielded wiring correctly and without delay.\u003c\/p\u003e\n\u003cp data-end=\"3157\" data-start=\"3130\"\u003eNo backorders. No guessing.\u003c\/p\u003e\n\u003chr data-end=\"3162\" data-start=\"3159\"\u003e\n\u003ch2 data-end=\"3183\" data-start=\"3164\"\u003eSold By The Foot\u003c\/h2\u003e\n\u003cp data-end=\"3317\" data-start=\"3185\"\u003eOrder exactly the length you need.\u003cbr data-end=\"3222\" data-start=\"3219\"\u003eFuture spool options will be available for professional harness shops and high-volume builders.\u003c\/p\u003e\n\u003chr data-end=\"3322\" data-start=\"3319\"\u003e\n\u003ch2 data-end=\"3345\" data-start=\"3324\"\u003eInstallation Notes\u003c\/h2\u003e\n\u003cp data-end=\"3477\" data-start=\"3347\"\u003eShield drain should be properly terminated at sensor ground or ECU-designated shield termination point depending on system design.\u003c\/p\u003e\n\u003cp data-end=\"3524\" data-start=\"3479\"\u003eProfessional wiring knowledge is recommended!\u003c\/p\u003e","brand":"VTI","offers":[{"title":"1","offer_id":48340220608766,"sku":"vti455","price":0.8,"currency_code":"USD","in_stock":true},{"title":"2","offer_id":48340220641534,"sku":"vti456","price":0.92,"currency_code":"USD","in_stock":true},{"title":"3","offer_id":48340220674302,"sku":"vti457","price":1.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0667\/7358\/2078\/files\/Mil-Spec_shielded_cable-harnessing.jpg?v=1781142828","url":"https:\/\/xtperformancemn.com\/products\/mil-dtl-27500-spec-55-shielded-cable-m22759-32-22-sold-by-the-foot","provider":"XT Performance","version":"1.0","type":"link"}